Ruijie Reyee SME RG-CS83-48GT4XS-PD Ruijie 48-Port 1GE RJ45 Layer 3 Managed Access Switch with PoE+, 4-Port 10GE Uplink

RG-CS83-48GT4XS-PD Ruijie 48-Port 1GE RJ45 Layer 3 Managed Access Switch with PoE+, 4-Port 10GE Uplink

Available
RRP RM22,980.00
Datasheet (PDF)

Features

  • 48-Port 10/100/1000 BASE-T,and 4 1G/10G SFP+ Ports,
  • support PoE+, max 1480w for PoE
  • 2 modular power supply slots at least one RG-PA600I-P-F/RG-PA1000I-P-F power module needed)

Specifications

Port Specifications

Fixed service port
48 x 10/100/1000BASE-T ports, supporting PoE/PoE+
4 x 1GE/10GE SFP+ ports
Module slot
2 x power module slots
Power module
RG-PA600I-P-F
RG-PA1000I-P-F
Fixed management ports
1 x RJ45 console port
1 x RJ45 MGMT port
USB
1 x USB port

System Specifications

Packet forwarding rate
132 Mpps
Switching capacity
176 Gbps
CPU
Dual-core CPU, each core with the clock speed of 1.2 GHz
BootROM
16 MB
Flash memory
2 GB
Memory
1 GB
Switch buffer
3 MB
MAC address table size
32,000
ARP table size
4,000
Number of IPv4 unicast routes
8,000
Number of IPv4 multicast routes
2,500
Number of IPv6 unicast routes
4,000
Number of IPv6 multicast routes
1,200
Number of ACEs
Ingress: 3,500
Egress:1,500
Number of VSU members
4
VLAN translation
4,094

Dimensions and Weight

Unit dimensions (W x D x H)
442 mm x 420 mm x 43.6 mm (17.40 in.x 16.54 in.x 1.72 in.)
Shipping dimensions (W x D x H)
570 mm x 565 mm x 172 mm (22.44 in. x 22.24 in. x 6.77 in.)
Rack height
1 RU
Unit weight
4.6 kg (10.14 lbs)
Shipping weight
6.98 kg (15.39 lbs)

Power Supply and Consumption

Power supply
2 x pluggable power modules
Power module redundancy
For dual power supplies, 1+1 power redundancy is supported only when the total PoE load of the device is less than the PoE output power of a single power supply.
Power input
RG-PA600I-P-F (AC input):
Rated input voltage: 100 V AC to 240 V AC, 50 Hz to 60 Hz
Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz
Maximum input current: 8 A
RG-PA1000I-P-F (AC input 1):
Rated input voltage: 100 V AC to 130 V AC, 50 Hz to 60 Hz
Maximum input voltage: 90 V AC to 143 V AC, 47 Hz to 63 Hz
Maximum input current: 12 A
RG-PA1000I-P-F (AC input 2):
Rated input voltage: 200 V AC to 240 V AC, 50 Hz to 60 Hz
Maximum input voltage: 180 V AC to 264 V AC, 47 Hz to 63 Hz
Maximum input current: 8 A
Maximum output power
RG-PA600I-P-F: 600 W
RG-PA1000I-P-F:
100 V AC to 130 V AC: 930 W
200 V AC to 240 V AC: 1000 W
Maximum power consumption
75 W (non-PoE)
1570 W (full PoE load)
PoE port
All RJ45 ports support PoE/PoE+ (IEEE802.3af/at) power supply
PoE power cable pairs
Mode A (1-2, 3-6 pairs)
PoE output power
Each PoE port provides up to 30 W of power
The maximum power depends on the configured power supply
1 x RG-PA600I-P-F: 370 W
2 x RG-PA600I-P-F: 740 W
1 x RG-PA1000I-P-F: 740 W
2 x RG-PA1000I-P-F: 1480 W, a maximum output of 1440 W over 48 ports (30 W x 48)
Energy saving
Supported

Environment and Reliability

Temperature
Operating temperature: 0°C to 45°C (32°F to 113°F)
Storage temperature: –40°C to +70°C (–40°F to +158°F)
Humidity
Operating humidity: 10% to 90% RH (non-condensing)
Storage humidity: 5% to 95% RH (non-condensing)
Altitude
Operating altitude: 0 m to 5,000 m (0 ft. to 16,404.20 ft.)
Storage altitude: 0 m to 5,000 m (0 ft. to 16,404.20 ft.)
Mean time between failure (MTBF)
315,000 hours (about 36 years, dual power modules)
193,000 hours (about 22 years, single power module)
Fan
1 x fixed fan module
Heat dissipation
Left-to-right and front-to-right airflow
Acoustic noise
27°C (80.6°F): 51.6 dB
45°C (113°F): 58.3 dB
Power module hot swapping
Supported
USB hot swapping
Supported
Cable hot swapping
Supported
Power supply monitoring
Monitoring of power supply model and status
Power supply fault alarming
Fan monitoring
Fan speed adjustment: 3 levels
Automatic speed adjustment
Fan failure alarming
Temperature monitoring
Temperature monitoring, over-temperature alarming
If the ambient temperature exceeds a certain value, the device will perform reset protection
ESD
ESD contact/air discharge: 6 kV/8 kV
ESD susceptibility contact/air discharge: 8 kV/15 kV
Surge protection
MGMT port: 4 kV
Service port: 10 kV
Power port: common mode 6 kV, differential mode 6 kV
Conformal coating
Conformal coating supported (key components only)

Certifications and Regulatory Compliance

Safety regulation
IEC 62368-1
EMC regulation
EN 300386, EN 55032 Class A, EN 55035, EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11
Communication standard
IEEE 802.3-2005 Ethernet standard
IEEE 803.ab, IEEE 802.3af, IEEE 802.1d, IEEE 802.1q, IEEE 802.3-2005 (802.3ae), and IEEE 802.3ba (2010) standards, supporting 802.1X authentication

Software Specifications

Ethernet switching
Jumbo frame (maximum length: 9216 bytes)
IEEE 802.1Q (4K VLANs)
Voice VLAN
Super VLAN and private VLAN
MAC VLAN, port-based VLAN, protocol-based VLAN, and IP-subnet based VLAN
GVRP
Basic QinQ
Selective QinQ
STP, RSTP, and MSTP
ERPS (G.8032)
LLDP/LLDP-MED
LACP (IEEE 802.3ad)
IP service
ARP
DHCP client, DHCP relay, and DHCP server
DHCP snooping
DNS
DHCPv6 client and DHCPv6 relay
DHCPv6 snooping
Neighbor Discovery (ND) and ND snooping
IP routing
Static routing
RIP, RIPng
OSPFv2, OSPFv3, IS-ISv4, ISv4, and IS-ISv6
BGP4 and BGP4+
IPv4 and IPv6 VRF
IPv4 and IPv6 PBR
Multicast
IGMP v1/v2/v3, and IGMP proxy
IGMP v1/v2/v3 snooping
PIM-DM, PIM-SM, and PIM-SSM
MSDP
MLD v1/v2
MLD snooping v1/v2
PIM-SMv6, PIM-SSM v6
ACL and QoS
Standard IP ACLs
Extended IP ACLs
Extended MAC ACLs
ACL80
IPv6 ACL
ACL redirection
Port traffic identification
Port traffic rate limiting
802.1p/DSCP/ToS traffic classification
Eight priority queues per interface
Traffic policing: CAR
Congestion management: RR, SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ
Congestion avoidance: tail drop, RED, and WRED
Rate limiting in each queue
Security
Multiple AAA modes
RADIUS and TACAS+
Port-based and MAC-based 802.1x authentication
Web authentication
Allowlist
HTTPS
SSHv1, SSHv2
Global IP-MAC binding
ICMP
Port isolation and port security
IP Source Guard
SAVI
Gateway ARP anti-spoofing
CPP(CPU Protection Policy
NFPP( Network Foundation Protection Policy
Strict and loose RPF
uRPF ignoring default routes
Reliability
REUP, RLDP, DLDP
IPv4 VRRP v2/v3 and IPv6 VRRP
BFD
Link tracing, fault notification, and remote loopback based on 802.3ah (EFM)
Hot swapping of power modules and cables
3-level fan speed adjustment
Fan fault alarm
Device virtualization
Virtual Switching Unit (VSU)
NMS and maintenance
SPAN, RSPAN, and ERSPAN
sFlow
NTP and SNTP
FTP and TFTP
SNMP v1/v2/v3
RMON (1, 2, 3, 9)
NETCONF
CWMP (TR-069) standard protocol
gRPC
Cloud and SON
PoE
IEEE 802.3af and 802.3at
Uninterruptible power supply upon hot start
Port priority
*Specifications are subject to change without prior notice.