Belden 10GXE02 006500M Belden 23AWG 10G S/FTP CAT6A Horizontal Cable

10GXE02 006500M Belden 23AWG 10G S/FTP CAT6A Horizontal Cable

New
  • CAT6A
  • 500m/box
RRP RM3,810.00
Datasheet (PDF)

Features

  • 23AWG Solid Bare Copper Conductors
  • 625MHz S/FTP, LSZH, 4 Pair
  • Polyethylene Insulation, LSZH Jacket

Specifications

Product Overview

Suitable Applications
Horizontal and building backbone cable, Support current and future Category 6A and 6 applications, such as: 10GBase-T (10 Gigabit Ethernet), 1000Base-T (Gigabit Ethernet), 100 Base-T, 10 Base-T, FDDI, ATM

Construction Details

Conductor
Individual Shielded Pair, 23 AWG Solid BC - Bare Copper, 4 pairs
Insulation
PE - Polyethylene (Foam), 1.32 mm (0.0520 in) nominal diameter, White & Blue, White & Orange, White & Green, White & Brown
Cable Core
4 pairs twisted together
Inner Shield
Individual Shielded Pair: Tape Bi-Laminate (Alum+Poly), 100% coverage, Aluminum facing outside
Outer Shield
Braid, Tinned Copper (TC), 30% coverage
Outer Jacket
LSZH - Low Smoke Zero Halogen (Flame Retardant), 6.9 mm (0.27 in) nominal diameter, Ripcord Yes
Overall Cable Diameter (Nominal)
7.0 mm (0.28 in)

Electrical Characteristics

Max. Conductor DCR
95 Ohm/km (29 Ohm/1000ft)
Max. Mutual Capacitance
56 pF/m (17 pF/ft)
Max. Capacitance Unbalance
160 pF/100m
Nom. Characteristic Impedance
100 Ohm
Max. Delay Skew
45 ns/100m
Nom. Velocity of Prop.
77%
Transfer Impedance
1 MHz: Max. 50 mOhm/m, 10 MHz: Max. 100 mOhm/m, 30 MHz: Max. 200 mOhm/m, 100 MHz: Max. 1000 mOhm/m
Transfer Impedance Class
Grade 2
Screening Class
Type Ib
Voltage Rating
72 V DC

Mechanical Characteristics

Operating Temperature
-30°C to +60°C
Installation Temperature
0°C To +60°C
Bend Radius (Stationary Min.)
29 mm (1.1 in)
Bend Radius (Installation Min.)
58 mm (2.3 in)
Max. Pull Tension
110 N (25 lbf)
Bulk Cable Weight
46 kg/km (31 lbs/1000ft)

Standards and Compliance

Environmental Suitability
Indoor - Euroclass Eca
Flammability / Reaction to Fire
IEC 60332-1-2
CPR Compliance
CPR Euroclass: Eca, CPR UKCA Class: Eca
IEEE Compliance
PoE: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4
Data Category
Category 6A
TIA/EIA Compliance
ANSI/TIA 568.2-D
ISO/IEC Compliance
ISO/IEC 11801-1
CENELEC Compliance
EN 50173-1, Segregation class according EN50174-2 = d
European Halogen Free Standards
IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 - Halogen Amount = Zero, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 2.5 µS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3, IEC 61034-2 - Smoke Density Min. Transmittance = 60%
European Directive Compliance
EU CE Mark
UK Regulation Compliance
UKCA Mark
Product Notes
Electrical values are expected performance based on cable testing and representative performance within a typical Belden system.
*Specifications are subject to change without prior notice.